Flow Cytometry Fluorescent Labels

The principle of flow cytometry is the segregation and analysis of cells which are arranged in a single line as they flow past a detector in a stream.

A machine sorts and counts the cells that have been labelled or tagged using fluorescent dyes or other methods.

The labels that are used depend on the lamp or laser that is used in the analyzer. This lamp or light excites the fluorochromes which are detected by the device.

There are several labels or fluorophores that are used in flow cytometry. These fluorophores or fluors are generally attached to an antibody that recognises a target feature either displayed on the cell or inside it.

Fluors can also be attached to a chemical that is attracted to a structure of the cell such as its membrane. Each of the fluors has a particular peak excitation and emission wavelength.

The types of labels used depends on the wavelength of the laser that excites the fluors as well as on the available detectors.

Sometimes, quantum dots are used instead of fluors because the dots have such narrow emission peaks.

In mass flow cytometery, multiple labelling is performed using lanthanide isotopes to antibodies. This allows for as many as 30 labels to be used.

Available labels

Examples of some of the labels available are given below:

  • Blue argon laser (488 nm) – This is an air-cooled laser and is therefore easier to set up and use. It is used in single laser machines. Some of the labels used for this laser include:
    • For Green channel on FL1 - Alexa Fluor 488, GFP, FITC, CFSE, DyLight 488 or CFDA-SE is used
    • For Orange channel on FL2 – PE or PI is used
    • For Red channel on FL3, usually - PE-Alexa Fluor 700, PerCP-Cy5.5, PerCP, PE-Cy5.5 or PE-Cy5 is used
    • For Infra-red channel usually on FL4 (this feature is not available for all flow cytometers) - PE-Cy7 or PE-Alexa Fluor 750 is used
  • Red diode laser (635 nm) – The labels used include APC-Cy7, APC-eFluor 780, Alexa Fluor 700, Cy5, APC, Draq-5
  • Violet laser (405 nm) – The labels used include Amine Aqua, Pacific Orange, Pacific Blue, DAPI, Alexa Fluor 405, eFluor 450, eFluor 605 Nanocrystals, eFluor 625 Nanocrystals or eFluor 650 Nanocrystals

Further Reading

Last Updated: Feb 26, 2019

Dr. Ananya Mandal

Written by

Dr. Ananya Mandal

Dr. Ananya Mandal is a doctor by profession, lecturer by vocation and a medical writer by passion. She specialized in Clinical Pharmacology after her bachelor's (MBBS). For her, health communication is not just writing complicated reviews for professionals but making medical knowledge understandable and available to the general public as well.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Mandal, Ananya. (2019, February 26). Flow Cytometry Fluorescent Labels. News-Medical. Retrieved on June 01, 2023 from https://www.news-medical.net/life-sciences/Flow-Cytometry-Fluorescent-Labels.aspx.

  • MLA

    Mandal, Ananya. "Flow Cytometry Fluorescent Labels". News-Medical. 01 June 2023. <https://www.news-medical.net/life-sciences/Flow-Cytometry-Fluorescent-Labels.aspx>.

  • Chicago

    Mandal, Ananya. "Flow Cytometry Fluorescent Labels". News-Medical. https://www.news-medical.net/life-sciences/Flow-Cytometry-Fluorescent-Labels.aspx. (accessed June 01, 2023).

  • Harvard

    Mandal, Ananya. 2019. Flow Cytometry Fluorescent Labels. News-Medical, viewed 01 June 2023, https://www.news-medical.net/life-sciences/Flow-Cytometry-Fluorescent-Labels.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post
You might also like...
Study shows SARS-CoV-2 causes DNA damage and elicits an altered DNA damage response